HyperStar 6v4 Installation Instructions
Starizona's HyperStar 6v4 converts a standard C6 telescope (SCT) into a high-speed, high-quality astrograph. The HyperStar lens allows for high-speed imaging at f/2 for a wider field, shorter exposures, and excellent image quality.
What’s Included?
If you purchased the Filter Slider Upgrade as an add-on to your HyperStar 6v4 order, then your HyperStar will also come with additional parts. These components are not included with the standard HyperStar package.
Pre-Installation Instructions
Before installing the HyperStar on your telescope, configure it for your specific telescope and camera setup. The HyperStar 6 v4 is shipped with the Standard Camera Adapter pre-installed. Depending on your setup, you may need to remove the standard camera adapter before continuing.
Complete the applicable steps below before proceeding to the HyperStar installation.
Pre-Installation Checklist
☐ If you purchased the Filter Slider Upgrade or a separate HyperStar Camera Adapter, remove the pre-installed Standard Camera Adapter.
The Standard Camera Adapter is installed on the HyperStar when it is shipped, including when the Filter Slider Upgrade is purchased. You will need to remove the Standard Camera Adapter before installing the filter slider; if it is left on, the backfocus will be incorrect.
If you purchased a separate HyperStar Camera Adapter, you will still need to unthread the Standard Camera Adapter and then thread on your other adapter. For more on ensuring you have the right adapter for your specific camera, see Choosing the Right HyperStar Camera Adapter.
Installing the HyperStar
Step 1: Remove the HyperStar bottom cap (secondary mirror holder).
Remove the bottom cap from the HyperStar lens by unthreading it. This cap will also hold the secondary mirror when it is removed from the telescope in Step 3.
Step 2. Point your telescope slightly upward.
Point your telescope’s optical tube slightly upward so the secondary mirror cannot fall out during Step 3. The photo below in Step 3 shows the appropriate angle.
Step 3. Remove the secondary mirror.
Start by unthreading the lock ring from the telescope’s secondary mirror holder. Then, lift the secondary mirror collimation plate and mirror out of the telescope. On the Celestron 6” SCT, there is not an easy place to grab the secondary collimation plate. For that reason, the HyperStar c6 includes a replacement plate with handle to make removing the mirror easier in the future (instructions on that below).
Step 4. Replace the secondary mirror collimation plate.
One-time procedure This step only needs to be completed the first time you install your HyperStar. The HyperStar C6 v4 includes a replacement secondary mirror collimation plate with a handle, making the secondary mirror easier to remove and reinstall in the future. If you have already replaced the original collimation plate, you can skip this step and proceed directly to Step 5.
Prepare the secondary mirror. Place the original secondary mirror face down on a clean, soft surface that will not scratch or contaminate the mirror. Lint-free optical cleaning wipes work well.
Note the original orientation. Before removing the original plate, take note of the orientation of the indexing screw on its side. The replacement plate must be installed in the same orientation.
Remove the original plate. Remove the three collimation screws securing the original plate to the mirror. The plate can then be lifted away. Be careful to keep the mirror in the same orientation.
Install the replacement plate. Place the new collimation plate onto the mirror, aligning its indexing screw with the same orientation as the original. Use the three screws included with the replacement plate to attach it.
Check the alignment. Once all three screws are partially threaded in, lift the mirror and plate assembly and look at it from the side. Adjust the screws to leave an approximately even gap between the mirror and plate. This helps ensure the mirror is reasonably close to the correct position for collimation when reinstalled. Avoid tilting the mirror excessively, as this will make collimation much more difficult.
Once installed, the replacement plate can remain on the secondary mirror permanently. Its handle will make future removal and reinstallation easier.
Step 5. Store the secondary mirror.
Place the secondary mirror into the included holder (the bottom cap from the HyperStar), making sure the index screw goes into the notch cut out for it. Then, thread on the lock ring from the telescope to keep the mirror safe.
Step 6. Thread the HyperStar lens onto the telescope.
The threads are fine and this can be tricky in the dark. Make sure the HyperStar is not tilted relative to the scope; it can help to stand to the side of the scope where you can see that the HyperStar is going in square.
IMPORTANT: Do not over-tighten the HyperStar on the telescope. If it is cold, the metal can shrink and it can be very difficult to remove the HyperStar. It only needs to go on until the threads just bottom out.
Step 6: Install a Filter
Option 1: Install a filter in the standard HyperStar Camera Adapter
To install a filter in the standard camera adapter, remove the top portion of the adapter by unthreading it. It has M48 female threads inside for installing standard 2” mounted filters. Starizona makes optional adapters to step down to other filter sizes if needed; see our 2” to 1.25” Filter Adapter.
Option 2: Install a filter into the Starizona Filter Slider
If you purchased the Starizona Filter Slider Upgrade, you can use it in place of the standard camera adapter to make changing filters easier.
Before installing the Filter Slider, make sure you have removed the pre-installed Standard Camera Adapter as described in the Pre-Installation Checklist. The Filter Slider Upgrade includes a dedicated HyperStar Filter Slider Adapter, which is pre-installed on the bottom of the slider assembly.
Thread the Filter Slider assembly onto the HyperStar, using the included adapter. The slider includes interchangeable threaded top plates to accommodate different camera connections. Select the appropriate top plate for your camera:
M42: For cameras with M42 threads.
M54: For cameras with M54 threads.
The Filter Slider uses a removable magnetic drawer that holds a standard 2" mounted filter. Simply insert your desired filter into the drawer and slide it into the filter holder.
Step 7. Rotate the HyperStar and Camera for Framing
The HyperStar and camera can be rotated together to allow for framing celestial targets. To rotate the HyperStar, slightly loosen the three thumb screws with the large white bushings. After rotating the HyperStar, tighten the topmost thumb screw first to pull the HyperStar up against gravity to seat it flat against its mounting rings, then tighten the other two screws.
What’s Next? Getting the Most Out of Your HyperStar
With your HyperStar installed and camera attached, you're ready to start setting up your imaging system. Depending on your equipment and experience, there are a few additional things you may need to address before your first imaging session.
Check collimation: Proper optical alignment is essential for getting sharp stars across the entire image. See Collimation & Optical Alignment for instructions on collimating your HyperStar.
Confirm backfocus and achieve focus: Make sure your camera and adapter combination provides the correct backfocus distance, and familiarize yourself with the focusing process. See Choosing the Right HyperStar Camera Adapter and Achieving Focus.
Optimize image quality: Learn about image circles, vignetting, cable management, and other factors that affect your final images. See Imaging & Performance.
Troubleshoot common issues: If you have difficulty reaching focus, notice elongated stars, or encounter other problems, our Troubleshooting & FAQs section can help identify the cause.
For additional technical information, including focal length, focal ratio, image circle, and backfocus specifications for your particular model, visit the HyperStar Reference Library.
Next article: HyperStar Backfocus Requirements












