Step 2: Coarse Collimation

Edited

Coarse Collimation (Out-of-Focus Star Method)

The goal of this step is not perfection, but to bring the system close enough that fine collimation can be done reliably afterward. This method uses a slightly defocused star to reveal tilt in the optical system and is the fastest way to diagnose and correct major alignment errors.

At f/2, even small misalignments are visible, but they can also be misleading if the setup is not done carefully. Taking a few moments to prepare properly will save a lot of frustration later.

Setup Requirements

Before making any collimation adjustments, make sure the following conditions are met:

1. Use a real star at night

Coarse collimation must be done under the night sky using a real star. Indoor setups and artificial stars can be useful for preliminary checks, but they are not sufficient for accurate HyperStar collimation. The optical geometry at f/2 is simply too sensitive.

2. Center the star in the field of view

Ensure the star is centered in the image. This is critical — off-axis stars will always look distorted, even in a perfectly collimated system, and will mislead you if used for adjustment.

3. Slightly defocus the star

Defocus the star just enough to produce a clearly visible donut shape. Avoid over-defocusing. If the donut becomes very large, it can look deceptively symmetrical even when collimation is off.

Above: Out-of-focus: the star appears as a large, round, donut-shaped disk.

4. Zoom in on the image

Zoom the image to approximately 100–200% so the donut shape can be evaluated accurately.

What You’re Looking For

In a properly collimated HyperStar system, the out-of-focus star will appear as a clean, symmetrical donut. The central shadow will be centered, the donut will have even thickness all the way around, and no side will appear pinched or stretched.

Above: A well-collimated defocused star image.

If one side of the donut is noticeably thinner than the opposite side, this indicates tilt. The asymmetry tells you that a collimation adjustment is needed.

Above: Appearance of an un-collimated defocused star

Finding the Correct Adjustment (Hand-Shadow Method)

The hand-shadow method helps you identify the direction of tilt to investigate before making an adjustment.

Briefly hold your hand in front of the telescope's aperture while watching the out-of-focus star:

  • Your hand will cast a shadow into the donut.

  • Move your hand around the aperture until the shadow aligns with the thick or thin part of the donut.

  • Note the direction of that part of the image relative to the telescope. This gives you a direction to investigate when choosing which screw pair to adjust.

Above: Finding the correct collimation screws to adjust by pointing to the narrow part of the donut

The hand-shadow method is a guide, not a guarantee that the first adjustment will improve the image. You'll confirm the correct direction by making a small adjustment and checking whether the donut becomes more symmetrical.

Adjustment Process (Step-by-Step)

Once you've identified the direction of tilt to test, make a small adjustment and check the result before proceeding further.

1. Lift one screw pair

Each of the three collimation points has a matched push/pull screw pair. The shorter screw is the pull screw, and the longer screw is the push screw.

To lift one side of the HyperStar:

  1. Loosen the pull screw slightly.

  2. Tighten the matching push screw.

Start with a very small adjustment, approximately 1/8 turn. For a more detailed explanation of the screws and the correct mechanical starting position, see Step 1. HyperStar Collimation Starting Position.

2. Re-center the star

After every adjustment, re-center the star in the field of view. Adjustments can shift the image, and collimation must always be evaluated with the star centered.

3. Recheck the donut shape

Examine the defocused star again at 100–200% zoom. Has the donut become more symmetrical, or has the asymmetry increased? Only very small adjustments are needed. Less than 1 full turn on the screws should be all that is required to collimate the HyperStar.

4. Follow the result

  • If the donut becomes more symmetrical: You've moved in the correct direction. Continue with small adjustments as needed, re-centering the star after each change.

  • If the donut becomes less symmetrical: You've likely tested the wrong direction of tilt. Reset the adjustment before trying the opposite direction.

5. What If the Adjustment Makes Things Worse?

Don't worry—this doesn't necessarily mean anything is wrong! You may simply have lifted the wrong side of the HyperStar.

To try the opposite direction:

  1. Return the screw pair you just adjusted to its original starting position. Restore the neutral position, with the tilt plates evenly seated.

  2. Lift the opposite screw set. Instead of trying to push the original side downward, raise the opposite side by making equal adjustments to the other two pairs. This creates the opposite direction of tilt while maintaining the intended mechanical arrangement.

  3. Re-center the star and check the donut again. If the donut becomes more symmetrical, continue making small adjustments in that direction.

Do not try to correct the result by tightening a pull screw to force one side downward. Collimation adjustments are made by lifting one side relative to the others.

6. Repeat Slowly

Most systems require adjustment of only one or two screw pairs, and the total movement is usually very small. Work in approximately 1/8-turn increments, checking the star image after each adjustment.

At f/2, small changes can have a noticeable effect, so avoid making several adjustments without checking the result!

Common Coarse Collimation Mistakes

  • Over-defocusing the star: Large donuts can hide real collimation errors.

  • Forgetting to re-center after adjustments: This is a common source of confusion during collimation.

  • Making large adjustments: Small changes go a long way. If an adjustment makes things worse, reset the screw pair and try the opposite direction.

What Comes Next?

Above: A well-collimated donut shape

Once the donut appears reasonably symmetrical, coarse collimation is complete! The system should now be close enough to move on to fine collimation, which uses in-focus stars and evaluates star shapes across the field.


Next article: Step 3: Fine Collimation

Was this article helpful?

Sorry about that! Care to tell us more?

Thanks for the feedback!

There was an issue submitting your feedback
Please check your connection and try again.