Step 1: HyperStar Collimation Starting Position

Edited

Before collimating your HyperStar, it's important to make sure it is in the correct mechanical starting position. This is the first step in the collimation process and helps ensure that subsequent adjustments are predictable and stable.

Even if you haven't adjusted the collimation screws yourself, it's worth checking that your HyperStar is in the correct starting position before you begin. And if you've already “messed with the screws” and are now wondering how to undo your handiwork, don't worry—you're in the right place! We'll walk you through getting everything back to the starting position.

This is especially important if:

  • You're preparing to collimate your HyperStar for the first time.

  • You've adjusted the collimation screws and want to reset them before continuing.

  • You've purchased a used HyperStar and aren't sure how the screws were previously adjusted.

  • Your collimation doesn't seem to hold between sessions.

What the Starting Position Looks Like

HyperStar collimation should always begin with the two tilt plates seated evenly against each other. There should be no large gaps, uneven spacing, shims, or added spacers between the plates.

You may notice a very slight gap at the outer edge of the rings even when they are correctly seated. This is normal and expected. The bottom ring is machined with a subtle bevel on its top surface to allow the HyperStar to tilt during collimation without binding. Because of this geometry, the plates can be properly seated while still showing a small, even gap along the outer edge.

This slight edge gap does not indicate that the rings are improperly spaced. What matters is that the plates are seated evenly, without a large or uneven gap.

Above: A slight gap at the outer edge of the rings is normal when the tilt plates are seated.

Understanding the Push/Pull Screw System

Each of the three collimation points on the HyperStar uses a matched pair of screws:

  • Pull screw: The shorter, stubby screw. It passes through the top ring and threads into the bottom mounting ring.

  • Push screw: The longer screw. It passes through the top ring and presses against the bottom ring.

Above: The collimation push/pull screw pair and the separate camera-rotation screw.

From the correct starting position, collimation adjustments are made by loosening the pull screw slightly and tightening the matching push screw. This lifts that side of the HyperStar relative to the mounting ring and changes its tilt.

To lift one side:

  1. Loosen the pull screw slightly.

  2. Tighten the matching push screw to lift that side of the HyperStar.

All collimation corrections are made by lifting one side relative to the others. Do not tighten a pull screw to force one side downward.

How to Return to the Starting Position

If your HyperStar has already been adjusted, or if you want to verify its starting position before beginning collimation, follow these steps to restore the tilt plates to their correct starting position.

  1. Loosen all six collimation screws. Back each screw off by approximately one full turn to release the existing adjustment and allow the plates to return to a neutral position.

  2. Bring the three short pull screws back into contact. Run each pull screw down until you just feel it touch the bottom mounting ring. Do not fully tighten the screws at this stage.

  3. Tighten the three longer push screws. Gently tighten each push screw to secure the plates in their starting position, keeping the contact even across all three collimation points.

  4. Check the starting position. The plates should be seated naturally against each other, without intentional spacing, shims, or spacers. Refer to the image in the previous section to confirm what the correct starting position should look like.

Avoid fully tightening one screw before the others. Doing so can introduce unintended tilt before collimation begins, making subsequent adjustments harder to interpret.

Remember that a slight, even gap at the outer edge of the rings is normal because of the bevel on the bottom ring. Do not try to eliminate it by forcing the plates together.

Ready to Begin Collimation?

Once the HyperStar is in the correct starting position, you're ready to begin optical alignment.

Continue to Step 2: Coarse Collimation to learn how to evaluate a defocused star, identify the direction of tilt to test, and make small adjustments to improve the symmetry of the star image.


Next article: Step 2: Course Collimation

Was this article helpful?

Sorry about that! Care to tell us more?